Summary for Test 2018-05-07-4-4
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 212618 DEA: 044G0564 EFIS: 0417000154 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-680-M2.4/M12.4 |
| Award Date | 11/16/2017 |
| Closeout Date | 12/08/2022 |
| Work Description | ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS |
| Location Description | FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/16/2017) |
Sample Information
| Sample Taken Date | 05/07/2018 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/14/2018 | Sample type | Quality Assurance |
| A brief description of the sample | UIltimate Welded Hoops | The quantity of what the sample constitutes | 8 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Lorenzo |
| Last name of sampler or witnessed by | Garcia | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | TNT Rebar |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | L11504518 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | NA1202000412 |
| Hoop Manufacturer Lot Number(s) | 1, 2 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 8 |
| Diameter of Hoop | 4'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-05-07-4
DIME Test ID: 2018-05-07-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-05-22
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/15/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 2 | #8/25mm | 0.79 | 80120 | 101420 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 5/15/2018 ✔