Summary for Test 2026-08-11-90-1

Test performed: AASHTO T315-24

Project Information

Project IdentifiersProject ID: 1001999
DEA: 044X5604
EFIS: 0426000094
DIST-CO-RTE-PM04-ALA-680-M0.01/M0.01
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/22/2026)

Sample Information

Sample Taken Date08/11/2026 Sample Unique Key90
Date that the sample was received by the laboratory/organization performing the testing08/31/2026 Sample typeProduction Start-Up
A brief description of the samplePG 58-22 The quantity of what the sample constitutes2 cans
From where was the sample collectedSupplier First name of sampler or witnessed byDennis
Last name of sampler or witnessed byYeung Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePNO
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number
Sublot number Tank number
Time of sample HMA SupplierVulcan Pleasanton Plant
Certified Asphalt SupplierPacific Northwest Oil - Stockton CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Type3/4 HMA 25% RAP HMA Supplier Mix ID Number320302W

Test Details

DIME Sample ID: 2026-08-11-90
DIME Test ID: 2026-08-11-90-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2026-09-01

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Amare Tefera
Date of test: 09/01/2026
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.06 %
Stress Amplitude: 0.171 kPa
Phase Angle (δ) (for the 10 cycles): 87.0 degree
Complex Modulus (G*) (for the 10 measurements): 1.419 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 1.42 kPa
General comments (publicly viewable) (Max 1000 characters): OG

Test was verified on 9/1/2026 ✔