Summary for Test 2026-08-22-21-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001404
DEA: 120S3804
EFIS: 1220000058
DIST-CO-RTE-PM12-ORA-5-10.0/21.3
Award Date10/20/2025
Closeout DateNot set
Work DescriptionSLAB REPLACEMENT (RSC), RHMA-PAVING, SIGNAL AND LIGHTING MODIFICATION.
Location DescriptionORANGE COUNTY FROM EL HORNO STREET UNDERCROSSING IN SAN JUAN CAPISTRANO TO ROUTE 405/5 SEPARATION IN IRVINE
QA Service Level1 (Verified on 09/08/2025)

Sample Information

Sample Taken Date08/22/2026 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing08/22/2026 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes3
From where was the sample collectedJob Site First name of sampler or witnessed byBrandon
Last name of sampler or witnessed byTran Title of sampler
Telephone number of sampler Laboratory sample identification26-0198
Linked DIME Sample ID The fabricator/manufacturer/facility nameSHORTLOAD CONCRETE INC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-08-22-21
DIME Test ID: 2026-08-22-21-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-09-01

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Brandon Tran
Date of test: 09/01/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.98 in
Average diameter of cylinder 3: 6.00 in
Maximum load on cylinder 1: 171570 lb
Maximum load on cylinder 2: 178860 lb
Maximum load on cylinder 3: 179620 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 10 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Cross sectional area of cylinder 3: 28.27 in^2
Compressive strength of cylinder 1: 6129.7 psi
Compressive strength of cylinder 2: 6367.4 psi
Compressive strength of cylinder 3: 6353.7 psi
Compressive strength (to nearest 10 psi): 6280 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
26-0198pdf137.18 KB09/01/20262026-08-22-21-1   Info

Test was verified on 9/1/2026 ✔