Summary for Test 2026-08-17-48-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 1001194
DEA: 051H4404
EFIS: 0516000074
DIST-CO-RTE-PM05-SB,SLO-1-50.3/50.6,0.0/0.3
Award Date09/30/2025
Closeout DateNot set
Work DescriptionSANTA MARIA RIVER BRIDGE (REPLACE).
Location DescriptionSANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE
QA Service Level1 (Verified on 06/02/2025)

Sample Information

Sample Taken Date08/17/2026 Sample Unique Key48
Date that the sample was received by the laboratory/organization performing the testing08/19/2026 Sample typeQuality Assurance
A brief description of the sample HRC 500-510 coupler The quantity of what the sample constitutes48
From where was the sample collectedJob Site First name of sampler or witnessed byGarret
Last name of sampler or witnessed byHilton Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor HRC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHRC Nucor Intermediate Assembler or Fabricator
Rebar Size#10 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)74141308 74143700 Rebar Heat Number(s)3500041544
Rebar Size 2 Coupler Unique IDTPT-17-04

Test Details

DIME Sample ID: 2026-08-17-48
DIME Test ID: 2026-08-17-48-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2026-09-01

Test Results


Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 09/01/2026
UTM: NA
Halo ID: na
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111101.270.00511791093000ok neckingKleinfelder
221101.27000011670092000ok neckingKleinfelder
331101.27000011700092000ok neckingKleinfelder
441101.27000011955094000ok neckingKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/1/2026 ✔