Summary for Test 2026-08-22-19-5
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 995520 DEA: 041Y7004 EFIS: 0423000016 |
|---|---|
| DIST-CO-RTE-PM | 04-CC,SOL-80-13.8/14.1,0.0/0.4 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | AL ZAMPA BRIDGE DECK REHABILITATION REPLACE TOP COURSE |
| Location Description | CONTRA COSTA AND SOLANO COUNTIES AT CROCKETT AND IN VALLEJO FROM UNION PACIFIC RAILROAD OVERHEAD TO 0.8 MILE SOUTH OF ROUTE 80/29 SEPARATION |
| QA Service Level | 1 (Verified on 12/06/2023) |
Sample Information
| Sample Taken Date | 08/22/2026 | Sample Unique Key | 19 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/22/2026 | Sample type | Production Start-Up |
| A brief description of the sample | #3/8 HMA-A 16% RAP | The quantity of what the sample constitutes | 80 tons |
| From where was the sample collected | Source | First name of sampler or witnessed by | Casey |
| Last name of sampler or witnessed by | Farrington | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Martin Marrieta | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | 1 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/8 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | 75S25326L1 |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | San Juaquin | |
| RAP content (%) | 16 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-08-22-19
DIME Test ID: 2026-08-22-19-5
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-09-01
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: c
Date of test: 08/22/2026
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1159.2 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 30.6 grams | 97 % | |||||
| 247.8 grams | 79 % | |||||
| 458.0 grams | 60 % | |||||
| 633.7 grams | 45 % | |||||
| 763.3 grams | 34 % | |||||
| 879.5 grams | 24 % | |||||
| 980.9 grams | 15 % | |||||
| 1043.4 grams | 10.0 % | |||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/1/2026 ✔