Summary for Test 2026-07-30-87-7

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 1001687
DEA: 11430344
EFIS: 1118000104
DIST-CO-RTE-PM11-SD-5,54,94,125-Var
Award DateNot set
Closeout DateNot set
Work DescriptionCULVERTS RESTORATION, RHMA, JPCP, ISR, BARRIER, LANDSCAPE, ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 02/05/2026)

Sample Information

Sample Taken Date07/30/2026 Sample Unique Key87
Date that the sample was received by the laboratory/organization performing the testing07/31/2026 Sample typeVerification
A brief description of the sampleJMF The quantity of what the sample constitutes5 bags
From where was the sample collectedSupplier First name of sampler or witnessed byGerardo
Last name of sampler or witnessed byCordero Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMM Lakeside
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)See Mix
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number21217105T3

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
2026-08-33: HMA Aggregates (Size 1/2"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP22026-07-30-87-7

Test Details

DIME Sample ID: 2026-07-30-87
DIME Test ID: 2026-07-30-87-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-09-01

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 08/20/2026
Cumulative Mass RetainedCorrection FactorCumulative Percent Passing
1544.9 grams
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
122.6 grams-0.5 %92 %
203.0 grams-0.2 %87 %
533.5 grams-0.7 %65 %
796.9 grams-0.2 %48 %
994.9 grams-0.5 %35 %
1140.5 grams-0.7 %25 %
1263.3 grams0.1 %18 %
1350.6 grams0.8 %13 %
1408.9 grams1.1 %9.9 %
1423.6 grams
General comments (publicly viewable) (Max 1000 characters): N/A

Test was verified on 9/1/2026 ✔