Summary for Test 2026-08-17-74-2
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1000665 DEA: 081K4004 EFIS: 0819000031 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15-3.5/6.8 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC). |
| Location Description | TEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 08/17/2026 | Sample Unique Key | 74 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/18/2026 | Sample type | Acceptance |
| A brief description of the sample | RHMA-O SP 1/2" PG64-16 RB | The quantity of what the sample constitutes | 760.7 Tons @ 00:29 (8/18/26) |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Idris |
| Last name of sampler or witnessed by | Najjar | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | R.J. Noble — Corona Drum Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0014 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt Cut at R.J. Noble Corona Drum Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 51R003ARSPC |
Test Details
DIME Sample ID: 2026-08-17-74
DIME Test ID: 2026-08-17-74-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-08-31
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Maqsud Ahmed
Date of test: 08/18/2026
Clay Level (Test 1): 6.1
Sand Level (Test 1): 3.5
Clay Level (Test 2): 6.2
Sand Level (Test 2): 3.6
Clay Level (Test 3): 6.5
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 58
Sand Equivalent (Test 2): 59
Sand Equivalent (Test 3): 59
Sand Equivalent: 59
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/31/2026 ✔