Summary for Test 2026-08-21-42-5
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 212900 DEA: 051G6804 EFIS: 0515000063 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-101-16.2-20.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | US 101 PISMO CONGESTION RELIEF PROJECT |
| Location Description | IN SAN LUIS OBISPO COUNTY IN PSMO BEACH FROM PISMO OVERHEAD TO 0.5 MILE NORTH OF SHELL BEACH ROAD UC |
| QA Service Level | 1 (Verified on 09/30/2019) |
Sample Information
| Sample Taken Date | 08/21/2026 | Sample Unique Key | 42 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/22/2026 | Sample type | Quality Control |
| A brief description of the sample | 4x8 cylinders | The quantity of what the sample constitutes | 5 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Brenda |
| Last name of sampler or witnessed by | Amaya | Title of sampler | Field Technician |
| Telephone number of sampler | Laboratory sample identification | ES26-032, Set 1 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Alliance Ready Mix Arroyo Grande | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | Price St Wall STA 15+63 to 16+44.5 | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | ES26-032 |
|---|---|---|---|
| The truck number from where the sample was collected | Load 1 | The batch plant ticket number from where the sample was collected | 1 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | Set 1 | |
| A detailed description of where the material sample was collected | Price St Wall STA 15+63 to 16+44.5 | Where the material sample would have been placed if not sampled | |
| From Lot No. | 1 | Bag Lot No. | 1 |
Test Details
DIME Sample ID: 2026-08-21-42
DIME Test ID: 2026-08-21-42-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-09-18
Test Results
Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Kaus
Date of test: 08/28/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 39300 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 3130 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/18/2026 ✔