Summary for Test 2026-08-25-14-7

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 1000232
DEA: 09392304
DIST-CO-RTE-PM09-MNO-120,182-Var
Award DateNot set
Closeout DateNot set
Work DescriptionRECYCLE PAVEMENT, PLACE HMA, AND INSTALL GUARDRAIL.
Location DescriptionMONO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/15/2024)

Sample Information

Sample Taken Date08/25/2026 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2026
Sample typeAcceptance A brief description of the sample1/2 HMA SP R15
The quantity of what the sample constitutesHMA Sample 15 From where was the sample collectedJob Site
First name of sampler or witnessed bySalvador Last name of sampler or witnessed byZepeda
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Lee Vining Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-08-25-14
DIME Test ID: 2026-08-25-14-7
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2026-08-28

Test Results


Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 08/27/2026
HMA Production: Lab
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: 12500
Type and Amount of Anti-Stripping Additive: None
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 113 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 5.19 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 11.5 mm
Stripping Inflection Point (Wheel A): 17845
Stripping Inflection Point (Wheel B): 12683
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 15000
Impression at specified number of passes average: 8 mm
General comments (publicly viewable) (Max 1000 characters): HMA-15

Test was verified on 8/28/2026