Summary for Test 2026-07-28-50-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001723
DEA: 050N7064
EFIS: 0524000077
DIST-CO-RTE-PM05-SB-101-10.9/12.3
Award DateNot set
Closeout DateNot set
Work DescriptionSB 101 - Segment 4E North - Cabrillo
Location DescriptionNot set
QA Service Level1 (Verified on 11/03/2025)

Sample Information

Sample Taken Date07/28/2026 Sample Unique Key50
Date that the sample was received by the laboratory/organization performing the testing07/28/2026 Sample typeQuality Assurance
A brief description of the sampleConcrete Test Samples The quantity of what the sample constitutes81cy
From where was the sample collectedSupplier First name of sampler or witnessed byMike
Last name of sampler or witnessed byBennett Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCEMEX Santa Barbara
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1627310
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected32079774
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-07-28-50
DIME Test ID: 2026-07-28-50-3
Testing Lab: CT D05 - Carpinteria Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-08-27

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bryan Stewart
Date of test: 08/25/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 97200 lb
Maximum load on cylinder 2: 98640 lb
Maximum load on cylinder 3: 91630 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 7696.0 psi
Compressive strength of cylinder 2: 7810.0 psi
Compressive strength of cylinder 3: 7254.9 psi
Compressive strength (to nearest 10 psi): 7590 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/27/2026 ✔