Summary for Test 2026-07-30-32-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000541
DEA: 09374704
EFIS: 0918000019
DIST-CO-RTE-PM09-INY-168,395-17.6/18.3,114.9/117.8
Award Date02/21/2025
Closeout DateNot set
Work DescriptionHMA (TYPE A), MINOR CONCRETE, AND LIGHTING.
Location DescriptionINYO COUNTY IN AND NEAR BISHOP ON ROUTE 395 FROM 0.1 MILE SOUTH OF JAY STREET TO BARLOW LANE AND ON ROUTE 168 FROM PIONEER LANE TO ROUTE 395
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date07/30/2026 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/31/2026
Sample typeQuality Assurance A brief description of the sample6 4x8 concrete cylinders
The quantity of what the sample constitutes15 cubic yards From where was the sample collectedJob Site
First name of sampler or witnessed byDylan Last name of sampler or witnessed byCarapazza
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility name7/11 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure namePile at 395 and Clarke Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number851259C6
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected979026
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedWheel Barrow from Chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-07-30-32
DIME Test ID: 2026-07-30-32-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-08-27

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 08/27/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 72780 lb
Maximum load on cylinder 2: 73480 lb
Maximum load on cylinder 3: 71930 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5790.0 psi
Compressive strength of cylinder 2: 5845.7 psi
Compressive strength of cylinder 3: 5722.4 psi
Compressive strength (to nearest 10 psi): 5790 psi
General comments (publicly viewable) (Max 1000 characters): PCC 12 Piles at Clarke St & 395

Test was verified on 8/27/2026