Summary for Test 2026-08-18-52-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1002077 DEA: 033H5904 EFIS: 0318000017 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-80-R26.3/R55.2 |
| Award Date | 01/08/2026 |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/07/2026) |
Sample Information
| Sample Taken Date | 08/18/2026 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/21/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA-SP w/RAP PG 64-16 |
| The quantity of what the sample constitutes | 2 Boxes | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Sergio | Last name of sampler or witnessed by | Tostado |
| Title of sampler | Materials Tester | Telephone number of sampler | 8315884727 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 4 | HMA Mix Number | 30940432407S |
| Binder content (%) | 4.7 | Virgin binder PG | PG 64-16 |
| Design binder PG | PG 64-16 | Binder Supplier | SJR |
| RAP content (%) | 15 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-08-18-52
DIME Test ID: 2026-08-18-52-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-08-27
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Joshua Wilson
Date of test: 08/27/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7402.5 grams
Mass of oven-dry sample in air for Sample 1: 2637.2 grams
Mass of container filled with the sample and water for Sample 1: 9020.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.587
Theoretical maximum density at 25°C (77°F): 2579.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/27/2026 ✔