Summary for Test 2026-08-25-15-2

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 1000232
DEA: 09392304
DIST-CO-RTE-PM09-MNO-120,182-Var
Award DateNot set
Closeout DateNot set
Work DescriptionRECYCLE PAVEMENT, PLACE HMA, AND INSTALL GUARDRAIL.
Location DescriptionMONO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/15/2024)

Sample Information

Sample Taken Date08/25/2026 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2026
Sample typeAcceptance A brief description of the sample3/4" Shoulder Backing
The quantity of what the sample constitutes2 Bags of Shoulder Backing From where was the sample collectedJob Site
First name of sampler or witnessed bySalvador Last name of sampler or witnessed byZepeda
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHunewell Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Jobsite
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Yard
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-08-25-15
DIME Test ID: 2026-08-25-15-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-08-26

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 08/26/2026
Clay Level (Test 1): 12.5
Sand Level (Test 1): 3
Clay Level (Test 2): 12.4
Sand Level (Test 2): 2.9
Clay Level (Test 3): 12.5
Sand Level (Test 3): 2.9
Sand Equivalent (Test 1): 24
Sand Equivalent (Test 2): 24
Sand Equivalent (Test 3): 24
Sand Equivalent: 24
General comments (publicly viewable) (Max 1000 characters): SB-01

Test was verified on 8/26/2026