Summary for Test 2026-07-15-22-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994901 DEA: 112T3434 EFIS: 1120000081 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-5.1/8.3 |
| Award Date | 01/29/2024 |
| Closeout Date | Not set |
| Work Description | SOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 03/21/2024) |
Sample Information
| Sample Taken Date | 07/15/2026 | Sample Unique Key | 22 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/15/2026 |
| Sample type | Quality Control | A brief description of the sample | JPCP |
| The quantity of what the sample constitutes | 3 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | DP | Last name of sampler or witnessed by | Smith |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | associated ready mix otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CT632CP |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | NB 805 @ Telegraph Cyn Rd | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-07-15-22
DIME Test ID: 2026-07-15-22-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-08-27
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 08/26/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Average diameter of cylinder 3: 6.01 in
Maximum load on cylinder 1: 124075 lb
Maximum load on cylinder 2: 123045 lb
Maximum load on cylinder 3: 127860 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Cross sectional area of cylinder 3: 28.37 in^2
Compressive strength of cylinder 1: 4373.5 psi
Compressive strength of cylinder 2: 4337.2 psi
Compressive strength of cylinder 3: 4506.9 psi
Compressive strength (to nearest 10 psi): 4410 psi
General comments (publicly viewable) (Max 1000 characters): 42 Day - Break 3 Cylinders - Min 4373 psi, complies
Test was verified on 8/27/2026 ✔