Summary for Test 2026-08-24-29-3
Test performed: AASHTO T30-25Project Information
| Project Identifiers | Project ID: 1001669 DEA: 09379004 EFIS: 0919000004 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-R65.0/76.0 |
| Award Date | 12/24/2025 |
| Closeout Date | Not set |
| Work Description | FULL DEPTH RECYCLING, COLD PLANE, HMA AND CURB RAMPS. |
| Location Description | INYO COUNTY AT AND NEAR INDEPENDENCE FROM 3 MILES SOUTH OF MANZANAR REWARD ROAD TO 0.3 MILE NORTH OF SHABBELL LANE |
| QA Service Level | 1 (Verified on 10/13/2025) |
Sample Information
| Sample Taken Date | 08/24/2026 | Sample Unique Key | 29 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/24/2026 |
| Sample type | Acceptance | A brief description of the sample | 3/4" HMA-A-SP PG58-34M R18 |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jeff | Last name of sampler or witnessed by | Puente |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | HMA-149 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | RHB Plant Indy | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-08-24-29
DIME Test ID: 2026-08-24-29-3
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-08-26
Test Results
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Has the fine aggregate sample been reduced?: No
Is an aggregate correction factor used?: Yes
Was the aggregate obtained using ASTM D8159?: No
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 08/24/2026
Total mass of material in the sample: 2059.6 grams
Cumulative mass retained on the 2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 in. sieve: 0.0 grams
Cumulative mass retained on the 3/4 in. sieve: 74.9 grams
Cumulative mass retained on the 1/2 in. sieve: 311.5 grams
Cumulative mass retained on the 3/8 in. sieve: 474.5 grams
Cumulative mass retained on the #4 sieve: 1012.3 grams
Cumulative mass retained on the #8 sieve: 1344.3 grams
Cumulative mass retained on the #16 sieve: 1557.4 grams
Cumulative mass retained on the #30 sieve: 1702.3 grams
Cumulative mass retained on the #50 sieve: 1818.3 grams
Cumulative mass retained on the #100 sieve: 1904.3 grams
Cumulative mass retained on the #200 sieve: 1957.6 grams
Cumulative mass retained on the pan: 1972.1 grams
Aggregate correction factor for the 2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 3/4 in. sieve (% passing): -1.0 %
Aggregate correction factor for the 1/2 in. sieve (% passing): -0.2 %
Aggregate correction factor for the 3/8 in. sieve (% passing): -0.3 %
Aggregate correction factor for the #4 sieve (% passing): -1.1 %
Aggregate correction factor for the #8 sieve (% passing): -1.2 %
Aggregate correction factor for the #16 sieve (% passing): -0.9 %
Aggregate correction factor for the #30 sieve (% passing): -0.7 %
Aggregate correction factor for the #50 sieve (% passing): -0.5 %
Aggregate correction factor for the #100 sieve (% passing): -0.2 %
Aggregate correction factor for the #200 sieve (% passing): -0.1 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 95 %
Cumulative percent passing the 1/2 in. sieve: 85 %
Cumulative percent passing the 3/8 in. sieve: 77 %
Cumulative percent passing the #4 sieve: 50 %
Cumulative percent passing the #8 sieve: 34 %
Cumulative percent passing the #16 sieve: 23 %
Cumulative percent passing the #30 sieve: 17 %
Cumulative percent passing the #50 sieve: 11 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 4.9 %
General comments (publicly viewable) (Max 1000 characters): HMA-149 PP Gradation
Test was verified on 8/26/2026 ✔