Summary for Test 2026-07-08-7-7

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 1001640
DEA: 010N2904
EFIS: 0123000202
DIST-CO-RTE-PM01-DN-197,199-Var
Award DateNot set
Closeout DateNot set
Work DescriptionREPLACE BRIDGE, EXCAVATION, AND RETAINING WALLS.
Location DescriptionDEL NORTE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 09/22/2025)

Sample Information

Sample Taken Date07/08/2026 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/20/2026
Sample typeQuality Assurance A brief description of the sample3/4" X 12"
The quantity of what the sample constitutes3 OF 458 From where was the sample collectedSource
First name of sampler or witnessed byLorenzo Last name of sampler or witnessed byGarcia
Title of samplerQA Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Lindon UT Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL115-104-26 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)NONE
Heat Number(s)1000129255 Nut Mfg. Lot Number(s)none
Washer Mfg. Lot Number(s)none Bolt SpecificationA449
Bolt Length(s)12" Nut Specificationnone
Washer Specificationnone FinishGalvanize
Diameter/Size3/4 Bolt Mfg. Lot Number1000129255
Rocap Test Requirement(s)none Lubricant Requirements(s)none
Washer Inner Diameter(s)none

Test Details

DIME Sample ID: 2026-07-08-7
DIME Test ID: 2026-07-08-7-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-25

Test Results


Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/25/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A1000129255.754749000000000A449Atlas
21B1000129255.754751000000000A449Atlas
31C1000129255.754805000000000A449Atlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/25/2026