Summary for Test 2026-07-08-7-7
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1001640 DEA: 010N2904 EFIS: 0123000202 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-197,199-Var |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE, EXCAVATION, AND RETAINING WALLS. |
| Location Description | DEL NORTE COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 09/22/2025) |
Sample Information
| Sample Taken Date | 07/08/2026 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" X 12" |
| The quantity of what the sample constitutes | 3 OF 458 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
| Title of sampler | QA | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-104-26 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NONE |
|---|---|---|---|
| Heat Number(s) | 1000129255 | Nut Mfg. Lot Number(s) | none |
| Washer Mfg. Lot Number(s) | none | Bolt Specification | A449 |
| Bolt Length(s) | 12" | Nut Specification | none |
| Washer Specification | none | Finish | Galvanize |
| Diameter/Size | 3/4 | Bolt Mfg. Lot Number | 1000129255 |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) | none |
Test Details
DIME Sample ID: 2026-07-08-7
DIME Test ID: 2026-07-08-7-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-25
Test Results
Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/25/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 1000129255 | .75 | 47490 | 0000 | 0000 | A449 | Atlas |
| 2 | 1B | 1000129255 | .75 | 47510 | 0000 | 0000 | A449 | Atlas |
| 3 | 1C | 1000129255 | .75 | 48050 | 0000 | 0000 | A449 | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/25/2026 ✔