Summary for Test 2026-08-10-31-9
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 993825 DEA: 040Q30U4 EFIS: 0420000235 COOP: 042830A3,042830A4 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA,CC-680-R11.0/R21.9,R0.0/R0.9 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | PRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC |
| Location Description | ALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
| Sample Taken Date | 08/10/2026 | Sample Unique Key | 31 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/11/2026 | Sample type | Quality Assurance |
| A brief description of the sample | A325 HDG | The quantity of what the sample constitutes | 17890 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Joe |
| Last name of sampler or witnessed by | Barron | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Nucor HRC | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
|---|---|---|---|
| Heat Number(s) | 1000133498 | Nut Mfg. Lot Number(s) | NA |
| Washer Mfg. Lot Number(s) | NA | Bolt Specification | A325 |
| Bolt Length(s) | 2-1/4" | Nut Specification | NA |
| Washer Specification | NA | Finish | HOT DIP GALV |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | W000306071 |
| Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | NA |
| Washer Inner Diameter(s) | NA | Bolt Mill Supplier | Not set |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2026-08-10-31
DIME Test ID: 2026-08-10-31-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-25
Test Results
Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/25/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | W000306071 | 1 | 83785 | 0000 | 0000 | A325 | WSP |
| 2 | 1B | W000306071 | 1 | 83735 | 0000 | 0000 | A325 | WSP |
| 3 | 1C | W000306071 | 1 | 83495 | 0000 | 0000 | A325 | WSP |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/25/2026 ✔