Summary for Test 2026-06-25-69-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 1001248
DEA: 120K93U4
EFIS: 1224000084
DIST-CO-RTE-PM12-ORA-57,91-13.9/16.1,4.8/6.6
Award Date10/20/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location DescriptionANAHEIM AND PLACENTIA ON ROUTE 57 FROM WAGNER AVENUE OVERCROSSING TO 0.2 MILE NORTH OF MIRALOMA AVENUE OVERCROSSING AND ON ROUTE 91 FROM 0.1 MILE EAST OF ACACIA STREET UNDERCROSSING TO 0.2 MILE EAST OF LA PALMA AVENUE OVERCROSSING
QA Service Level1 (Verified on 06/16/2025)

Sample Information

Sample Taken Date06/25/2026 Sample Unique Key69
Date that the sample was received by the laboratory/organization performing the testing06/30/2026 Sample typeQuality Assurance
A brief description of the sample.6in Prestressing Strand The quantity of what the sample constitutes2
From where was the sample collectedFabricator First name of sampler or witnessed byMike
Last name of sampler or witnessed byGonzalez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S381250-2, S381253-7 Number of Coils
Group Number Strand Diameter
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0514626, S0253271 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2026-06-25-69
DIME Test ID: 2026-06-25-69-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-08-25

Test Results


Number of Samples: 2
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/25/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0514626S381250-20.2176371059260000012.5RMA
2S0253271S381253-70.2176298058770000012.1RMA

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/25/2026 ✔