Summary for Test 2026-08-13-61-1

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/13/2026 Sample Unique Key61
Date that the sample was received by the laboratory/organization performing the testing08/13/2026 Sample typeQuality Control
A brief description of the samplePG70-10 The quantity of what the sample constitutes1 of 2 cans
Sample sizeNot set From where was the sample collectedManufacturer
First name of sampler or witnessed byRICK Last name of sampler or witnessed byRAMOS
Title of sampler Telephone number of sampler
Laboratory sample identification7010260813 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refinery, Bakersfield, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number7010260813
Sublot number Tank number9001
Time of sample HMA SupplierN/A
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeN/A HMA Supplier Mix ID NumberN/A

Test Details

DIME Sample ID: 2026-08-13-61
DIME Test ID: 2026-08-13-61-1
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2026-08-25

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Fahrenheit and mmHg
Input Type: Calculated
Tester's full name: CHRIS FLORENCE
Date of test: 08/13/2026
Observed Flash Point: 582 F
Ambient Barometric Pressure: 762 mmHg
Cleveland Open-Cup Flash Point in Fahrenheit: 582 F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/25/2026 ✔