Summary for Test 2026-07-28-18-7

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994675
DEA: 07390204
EFIS: 0722000334
DIST-CO-RTE-PM07-LA-47-0.4 / 2.1
Award Date01/24/2025
Closeout DateNot set
Work DescriptionBridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints.
Location DescriptionRTE 47 between Terminal Island and San Pedro PM 0.4/2.1
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date07/28/2026 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing08/10/2026 Sample typeQuality Assurance
A brief description of the sample1" x 3-1/4" A325 Hex Bolt The quantity of what the sample constitutes404
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byAlvarez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUniversal Industrial Sales
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)10982920 Nut Mfg. Lot Number(s)N/A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationA325
Bolt Length(s)3-1/4" Nut SpecificationN/A
Washer SpecificationN/A FinishHDG
Diameter/Size1" Bolt Mfg. Lot NumberBG3361
Rocap Test Requirement(s)0 Lubricant Requirements(s)0
Washer Inner Diameter(s)0 Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2026-07-28-18
DIME Test ID: 2026-07-28-18-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-25

Test Results


Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Kevin De Souza
Date of test: 08/24/2026
UTM: NA
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AB6336118867000TensileKleinfelder
21BB6336118761000TensileKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/25/2026 ✔