Summary for Test 2026-07-27-3-1

Test performed: ASTM A722-18

Project Information

Project IdentifiersProject ID: 1001640
DEA: 010N2904
EFIS: 0123000202
DIST-CO-RTE-PM01-DN-197,199-Var
Award DateNot set
Closeout DateNot set
Work DescriptionREPLACE BRIDGE, EXCAVATION, AND RETAINING WALLS.
Location DescriptionDEL NORTE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 09/22/2025)

Sample Information

Sample Taken Date07/27/2026 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/05/2026
Sample typeQuality Assurance A brief description of the sampleA722 Threaded Bar System
The quantity of what the sample constitutes30 From where was the sample collectedFabricator
First name of sampler or witnessed bySherri Last name of sampler or witnessed byBrannon
Title of samplerQuality Assurance Inspector Telephone number of sampler9168266371
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameZ Systems, Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB22-039-26 Structure unique identifier
Structure name Bid Item3945790

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A772 Threaded Bar Grade150
Threaded Bar Type Rebar Size
Nut Specification for Threaded BarASTM A519 System ManufacturerThreaded Bars
Epoxy Coating ColorNA Threaded Bar Application
Coating StandardsUncoated Bar Heat Number(s)58068375
Nut Heat Number(s)C257139 Bar Lot Number
Nut Lot Number Coupler Heat Number(s)A246542
Coupler Grade150

Test Details

DIME Sample ID: 2026-07-27-3
DIME Test ID: 2026-07-27-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2026-08-25

Test Results


Number of Threaded Bar Samples: 3
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 08/24/2026
UTM: NA
Temperature: 0 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
111 3/4580683752.5815800013490000CouplerAtlas
221 3/4580683752.5815980014250090Bar W NutAtlas
331 3/4580683752.381533001359001230Reduction of AreaAtlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/25/2026