Summary for Test 2026-08-20-25-2

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1001613
DEA: 060V6104
EFIS: 0616000222
DIST-CO-RTE-PM06-KER-119-28.2/31.3
Award DateNot set
Closeout DateNot set
Work DescriptionHMA (TYPE A), RCP, CLASS 2 AB, ROADWAY EXC, AND MODIFYING SIGNAL.
Location DescriptionKERN COUNTY IN AND NEAR BAKERSFIELD FROM 0.1 MILE WEST OF ASHE ROAD TO ROUTE 119/99 SEPARATION
QA Service Level1 (Verified on 09/15/2025)

Sample Information

Sample Taken Date08/20/2026 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/21/2026
Sample typeAcceptance A brief description of the sample3/4" HMA- A 15% RAP
The quantity of what the sample constitutes3/4" HMA- Type A 15% RAP L1SL4 From where was the sample collectedSource
First name of sampler or witnessed byAlex Last name of sampler or witnessed byEscober
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith, Edmonston Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item3936252

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number4 HMA Mix Number
Binder content (%)4.7 Virgin binder PGPG 70-10
Design binder PGPG 70-10 Binder Suppliersan Joaquin refinery
RAP content (%)15 WMA AdditivesNo
Antistrip typeLime

Test Details

DIME Sample ID: 2026-08-20-25
DIME Test ID: 2026-08-20-25-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-08-21

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 08/21/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4328.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 6449.5 g
Mass of HMA Sample prior to ignition: 2121.5 g
Mass Loss: 107.7 g
Mass of aggregate remaining after ignition: 2013.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.69 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.39 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0V6104_37040_260820_T308_L1SL4pdf160.15 KB08/21/20262026-08-20-25-2   Info

Test was verified on 8/21/2026