Summary for Test 2026-08-17-51-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1002450
DEA: 033G6104
EFIS: 0324000347
DIST-CO-RTE-PM03-YOL-5-14/22.8
Award Date03/16/2026
Closeout DateNot set
Work DescriptionHM 1; REPLACE RHMA-O WITH DIGOUTS RTE 5 YOLO: COLD PLANE AC PAVEMENT, HMA (TYPE A), RHMA-O (OGFC), TACK COAT, TEMPORARY CHECK DAM & DRAINAGE INLET PROTECTION, THERMOPLASTIC STRIPING/MARKING (EWNV), RETROREFLECTIVE PAVEMENT MARKERS, RUMBLE STRIP
Location DescriptionNot set
QA Service Level1 (Verified on 08/03/2026)

Sample Information

Sample Taken Date08/17/2026 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/18/2026
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-O
The quantity of what the sample constitutes2 Boxes From where was the sample collectedSource
First name of sampler or witnessed byDavid Last name of sampler or witnessed byDrane
Title of samplerTET Telephone number of sampler
Laboratory sample identificationDaily Sample 26-217 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Woodland Transportation Laboratory (TL) NumberC766484
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number1
Sublot number14 HMA Mix Number30640542600P
Binder content (%)7.4 Virgin binder PGPG 64-16
Design binder PGPG 64-16 Binder SupplierPNW
RAP content (%)0 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2026-08-17-51
DIME Test ID: 2026-08-17-51-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-08-20

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 08/19/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1681.1 g
Mass Loss: 143.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.86 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.66 %
General comments (publicly viewable) (Max 1000 characters): L1 OBC 7.4%

Test was verified on 8/20/2026