Summary for Test 2026-08-11-77-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1001360 DEA: 09374804 EFIS: 0918000020 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-115.0 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | BUILDING WORK AND PLACE HMA (TYPE A). |
| Location Description | INYO COUNTY IN BISHOP AT THE DISTRICT OFFICE AT 500 SOUTH MAIN STREET |
| QA Service Level | 1 (Verified on 07/09/2025) |
Sample Information
| Sample Taken Date | 08/11/2026 | Sample Unique Key | 77 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/12/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 9 PCC Cylinders 4x8 |
| The quantity of what the sample constitutes | 5cy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dylan | Last name of sampler or witnessed by | Carapazza |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | PCC-04 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | 7/11 Bishop | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Footings, Curbs Pre Cast Pads | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | First 1/4 of Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-08-11-77
DIME Test ID: 2026-08-11-77-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-08-19
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 08/19/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 44130 lb
Maximum load on cylinder 2: 45610 lb
Maximum load on cylinder 3: 43280 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3510.7 psi
Compressive strength of cylinder 2: 3628.5 psi
Compressive strength of cylinder 3: 3443.1 psi
Compressive strength (to nearest 10 psi): 3530 psi
General comments (publicly viewable) (Max 1000 characters): 7 Day Break
Test was verified on 8/19/2026 ✔