Summary for Test 2026-07-19-13-8
Test performed: AASHTO T313-2025Project Information
| Project Identifiers | Project ID: 1000777 DEA: 07370404 EFIS: 0720000128 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-R59.5/R73.7 |
| Award Date | 02/06/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PAVEMENT, PLACE HOT MIX ASPHALT AND INSTALL MGS. |
| Location Description | LOS ANGELES COUNTY FROM LAKE HUGHES ROAD UNDERCROSSING TO 0.7 MILE SOUTH OF VISTA DEL LAGO ROAD OVERCROSSING. |
| QA Service Level | 1 (Verified on 11/25/2024) |
Sample Information
| Sample Taken Date | 07/19/2026 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/24/2026 |
| Sample type | Verification | A brief description of the sample | Asphalt Binder Sample |
| The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
| First name of sampler or witnessed by | Stuwart Ahumada (QC) | Last name of sampler or witnessed by | Ahumada |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Griffith Edmonston-Lebec | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | N/A | |
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | N/A | HMA Supplier Mix ID Number | N/A |
Test Details
DIME Sample ID: 2026-07-19-13
DIME Test ID: 2026-07-19-13-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2026-08-20
Test Results
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 08/19/2026
Paired test specimens performed?: no data
BBR Software for individual test specimens: no data
Maximum test bath temperature at 240 S: 0.0 C
Minimum test bath temperature at 240 S: 0.0 C
Time of test load application: no data
File name of test data: no data
Time test specimen in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficients and least square fit R² value: 0.000
Comments: no data
Regression coefficient a: 0.000
Regression coefficient b: 0.000
Regression coefficient c: 0.000
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Loading time 8.0 s: 0.0 s
Load at 8.0 s: 0.0 mN
Test specimen deflection 8.0 s: 0.000 µm
Measured Stiffness Modulus 8.0 s: 0.000 MPa
Estimated Stiffness Modulus 8.0 s: 0.000 MPa
Difference between stiffness moduli 8.0 s: 0.00 %
Estimated m-value 8.0 s: 0.000
Loading time 15.0 s: 0.0 s
Load at 15.0 s: 0.0 mN
Test specimen deflection 15.0 s: 0.000 µm
Measured Stiffness Modulus 15.0 s: 0.000 MPa
Estimated Stiffness Modulus 15.0 s: 0.000 MPa
Difference between stiffness moduli 15.0 s: 0.00 %
Estimated m-value 15.0 s: 0.000
Loading time 30.0 s: 0.0 s
Load at 30.0 s: 0.0 mN
Test specimen deflection 30.0 s: 0.000 µm
Measured Stiffness Modulus 30.0 s: 0.000 MPa
Estimated Stiffness Modulus 30.0 s: 0.000 MPa
Difference between stiffness moduli 30.0 s: 0.00 %
Estimated m-value 30.0 s: 0.000
Loading time 60.0 s: 0.0 s
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Test specimen deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 0.000 MPa
Estimated Stiffness Modulus 60.0 s: 221.082 MPa
Difference between stiffness moduli 60.0 s: 0.00 %
Estimated m-value 60.0 s: 0.356
Loading time 120.0 s: 0.0 s
Load at 120.0 s: 0.0 mN
Test specimen deflection 120.0 s: 0.000 µm
Measured Stiffness Modulus 120.0 s: 0.000 MPa
Estimated Stiffness Modulus 120.0 s: 0.000 MPa
Difference between stiffness moduli 120.0 s: 0.00 %
Estimated m-value 120.0 s: 0.000
Loading time 240.0 s: 0.0 s
Load at 240.0 s: 0.0 mN
Test specimen deflection 240.0 s: 0.000 µm
Measured Stiffness Modulus 240.0 s: 0.000 MPa
Estimated Stiffness Modulus 240.0 s: 0.000 MPa
Difference between stiffness moduli 240.0 s: 0.00 %
Estimated m-value 240.0 s: 0.000
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/20/2026 ✔