Summary for Test 2026-07-27-96-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1002252
DEA: 070Y7304
EFIS: 0725000155
DIST-CO-RTE-PM07-UNKNOWN--unknown
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 05/29/2026)

Sample Information

Sample Taken Date07/27/2026 Sample Unique Key96
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/04/2026
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byGC (AAA& SEQUOIA) Last name of sampler or witnessed byGC (AAA& SEQUOIA)
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-07-27-96
DIME Test ID: 2026-07-27-96-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-08-19

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 08/17/2026
Time of test: 8:48 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 74.2 %
Viscosity reading #1 (A) : 0.37 Pa-s
Viscosity reading #2 (B) : 0.371 Pa-s
Viscosity reading #3 (C): 0.372 Pa-s
Average viscosity: 0.371 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/19/2026