Summary for Test 2026-07-26-18-2

Test performed: ASTM D36-14ε1

Project Information

Project IdentifiersProject ID: 1002542
DEA: 101U0404
EFIS: 1025000084
DIST-CO-RTE-PM10-SJ-26-unk1.1/8.0, 10.1/11.0known
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, HMA, RHMA, slurry seal, and signal and lighting systems
Location DescriptionFROM 0.3 MILE WEST OF ORO AVENUE TO 0.9 MILE WEST OF MURRAY ROAD AND AT LINDEN FROM 0.1 MILE EAST OF DUNCAN ROAD TO 0.2 MILE EAST OF MARKET STREET In District 10 On Route 26
QA Service Level1 (Verified on 08/12/2026)

Sample Information

Sample Taken Date07/26/2026 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/11/2026
Sample typeQuality Assurance A brief description of the sample1 can of rubberized binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSource
First name of sampler or witnessed byLuis Last name of sampler or witnessed byMagana
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGeorge Reed Munn & Perkins Plant Transportation Laboratory (TL) Number850391
Inspector Lot Number from the Transportation Laboratory (TL) Form850391 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2026-07-26-18
DIME Test ID: 2026-07-26-18-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2026-08-18

Test Results


ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 08/18/2026
Softening Point Sample 1: 67 C
Softening Point Sample 2: 67 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): SOFTENING POINT

Test was verified on 8/18/2026