Summary for Test 2026-07-31-2-1
Test performed: ASTM A615-20Project Information
| Project Identifiers | Project ID: 1001281 DEA: 11430234 EFIS: 1118000029 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-0.1/14.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | REPLACE CONC PVMT, CONSTRUCT AUX LANE & BIKE TRAIL, ELECT, & LANDSCAPE |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO, CHULA VISTA AND NATIONAL CITY FROM 0.3 MILE SOUTH OF ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION |
| QA Service Level | 1 (Verified on 06/09/2025) |
Sample Information
| Sample Taken Date | 07/31/2026 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/11/2026 | Sample type | Quality Assurance |
| A brief description of the sample | #9 Gr 75 (ASTM A615) All Thread Bar and Hex Nuts | The quantity of what the sample constitutes | 11 pcs |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Johnathan |
| Last name of sampler or witnessed by | Shoulders | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Williams Form Engineering | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
| Threaded Bar Type | Rebar Size | ||
| Nut Specification for Threaded Bar | ASTM A29/A108 | System Manufacturer | Williams Form Engineering San Diego |
| Epoxy Coating Color | NA | Threaded Bar Application | |
| Coating Standards | Uncoated | Bar Heat Number(s) | 1000235791 |
| Nut Heat Number(s) | 1000128766 | Bar Lot Number | |
| Nut Lot Number | Coupler Heat Number(s) | ||
| Coupler Grade |
Test Details
DIME Sample ID: 2026-07-31-2
DIME Test ID: 2026-07-31-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2026-08-18
Test Results
Number of Samples: 2
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/18/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 9 | 1000235791 | 1 | 108000 | 83890 | 0000 | A615 Bar and Nut | Kleinfelder |
| 2 | 2 | 9 | 1000235791 | 1 | 126000 | 98810 | 9 | A615 Bar | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):