Summary for Test 2026-08-17-19-2

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 1001645
DEA: 051R1004
EFIS: 0523000125
DIST-CO-RTE-PM05-SLO, -1-32.6
Award DateNot set
Closeout DateNot set
Work DescriptionBRIDGE REPLACEMENT, HMA, AND RSP PROTECTION.
Location DescriptionSAN LUIS OBISPO COUNTY NEAR MORRO BAY AT TORO CREEK BRIDGE
QA Service Level1 (Verified on 11/03/2025)

Sample Information

Sample Taken Date08/17/2026 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing08/17/2026 Sample typeAcceptance
A brief description of the sample770RMR3810 Aggregate The quantity of what the sample constitutes8/17/26 Pour - 770RMR3810 CIDH
From where was the sample collectedManufacturer First name of sampler or witnessed byIsaac
Last name of sampler or witnessed byChezem Title of samplerCT Tester
Telephone number of sampler Laboratory sample identification260817-1 770RMR3810
Linked DIME Sample ID The fabricator/manufacturer/facility nameCalPortland - San Luis Obispo
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name8/17/26 CIDH Pour
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-40-0013
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number770RMR3810 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-08-17-19
DIME Test ID: 2026-08-17-19-2
Testing Lab: CT D05 - Paso Robles Field Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2026-08-17

Test Results


Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 08/17/2026
Top sediment column reading (single primary size): 0.5 in
Cleanness value (single primary size): 86
General comments (publicly viewable) (Max 1000 characters): 3/8" Agg

Test was verified on 8/17/2026 ✔