Summary for Test 2026-06-25-8-13
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1001625 DEA: 11173704 EFIS: 1100020255 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-2.6/3.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | WIDEN INTERCHANGE, STRUCTURES, HMA-A, RHMA-G, LANDSCAPE, & ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF PALM AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 03/04/2026) |
Sample Information
| Sample Taken Date | 06/25/2026 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/25/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 1"x30" Double End Studs |
| The quantity of what the sample constitutes | 101 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jayce | Last name of sampler or witnessed by | Groves |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Halo | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | No |
|---|---|---|---|
| Heat Number(s) | 79020498, 8000028822, 190250877 | Nut Mfg. Lot Number(s) | W000222814 |
| Washer Mfg. Lot Number(s) | E8885 | Bolt Specification | F1554 |
| Bolt Length(s) | 30" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | N/A |
| Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
| Washer Inner Diameter(s) | one one eight |
Test Details
DIME Sample ID: 2026-06-25-8
DIME Test ID: 2026-06-25-8-13
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-18
Test Results
Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 08/14/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | W000222814 | 1 | 106050 | 0 | 0 | Nut Proof Load | Kleinfelder |
| 2 | 1B | W000222814 | 1 | 106050 | 0 | 0 | Nut Proof Load | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2026 ✔