Summary for Test 2026-07-31-4-1
Test performed: ASTM A970-18Project Information
| Project Identifiers | Project ID: 1001469 DEA: 120K62U4 EFIS: 1224000090 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA,-5-R25.8/30.3 |
| Award Date | 11/12/2025 |
| Closeout Date | Not set |
| Work Description | CONST BRIDGE, RW, SW, PAVEMENT, DRAINAGE, AND ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN IRVINE AND TUSTIN FROM YALE AVENUE OVERCROSSING TO ROUTE 5/55 SEPARATION |
| QA Service Level | 1 (Verified on 08/13/2025) |
Sample Information
| Sample Taken Date | 07/31/2026 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/06/2026 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM A706 GR 60 Size #9 HRC 555 Headed Bar | The quantity of what the sample constitutes | 16 Headed Bar HRC 555 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Martinez Steel | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 256426 | Head Manufacturer Lot Number(s) | NA |
| Rebar Size | #9 | Headed Bar Model Name | HRC 555 |
| Size of Head | Full Size - 9x | Head Connection Type | |
| Head Shape | Circular | Rebar Manufacturer | Cascade Steel Rolling Mills - Oregon |
| Head Manufacturer | Martinez steel | Head Fabricator | Martinez Steel |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 4FG-17-01 |
Test Details
DIME Sample ID: 2026-07-31-4
DIME Test ID: 2026-07-31-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2026-08-14
Test Results
Number of Headed Bar Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/14/2026
UTM: NA
Temperature: 0 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 98060 | 98000 | Ok Necking | Kleinfelder |
| 2 | 1 | 1 | 94610 | 94500 | Ok Necking | Kleinfelder |
| 3 | 1 | 1 | 97840 | 98000 | Ok Necking | Kleinfelder |
| 4 | 1 | 1 | 98680 | 98500 | Ok Necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/14/2026 ✔