Summary for Test 2026-06-25-13-18
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1001625 DEA: 11173704 EFIS: 1100020255 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-2.6/3.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | WIDEN INTERCHANGE, STRUCTURES, HMA-A, RHMA-G, LANDSCAPE, & ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF PALM AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 03/04/2026) |
Sample Information
| Sample Taken Date | 06/25/2026 | Sample Unique Key | 13 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/05/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 1"x13" All Thread Studs | The quantity of what the sample constitutes | 207 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Jayce |
| Last name of sampler or witnessed by | Groves | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Halo | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | No |
|---|---|---|---|
| Heat Number(s) | 245879, 8000029706, 32312470 | Nut Mfg. Lot Number(s) | W000184115 |
| Washer Mfg. Lot Number(s) | E6242 | Bolt Specification | F1554 GR55 |
| Bolt Length(s) | 13" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | Galvanized |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 245879 |
| Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
| Washer Inner Diameter(s) | one one eight | Bolt Mill Supplier | Not set |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2026-06-25-13
DIME Test ID: 2026-06-25-13-18
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-18
Test Results
Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 08/14/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 8000029706 | 1 | 106050 | 0 | 0 | Nut Proof Load | Kleinfelder |
| 2 | 1B | 8000029706 | 1 | 106050 | 0 | 0 | Nut Proof Load | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2026 ✔