Summary for Test 2026-06-22-92-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000513 DEA: 020J8504 EFIS: 0219000168 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-89-21/R34.622 |
| Award Date | 08/05/2025 |
| Closeout Date | Not set |
| Work Description | MCCLOUD CAPM - PAVEMENT REHABILITATION |
| Location Description | IN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5 |
| QA Service Level | 1 (Verified on 08/12/2024) |
Sample Information
| Sample Taken Date | 06/22/2026 | Sample Unique Key | 92 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/22/2026 |
| Sample type | Production Start-Up | A brief description of the sample | 16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-16) |
| The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Delgado |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D80242 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 895737 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | JMF 2606P01 | |
| Binder content (%) | 4.7 | Virgin binder PG | PG 58-22 |
| Design binder PG | PG 64-16 | Binder Supplier | Albina (Klamath Falls, OR) |
| RAP content (%) | 25 | WMA Additives | |
| Antistrip type | Lime |
Test Details
DIME Sample ID: 2026-06-22-92
DIME Test ID: 2026-06-22-92-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-08-14
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Sean McWhithey
Date of test: 07/06/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3159.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5211.4 g
Mass of HMA Sample prior to ignition: 2051.5 g
Mass Loss: 113.0 g
Mass of aggregate remaining after ignition: 1938.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.58 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.81 %
General comments (publicly viewable) (Max 1000 characters): Pb=4.81%
Test was verified on 8/14/2026 ✔