Summary for Test 2026-07-30-72-1
Test performed: ASTM D217-21Project Information
| Project Identifiers | Project ID: 1001306 DEA: 023H7704 EFIS: 0218000039 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-99-0.0/12.5 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | VINA REHAB: PLACE HMA, INSTALL CULVERTS, AND INSTALL GUARDRAIL. |
| Location Description | TEHAMA COUNTY IN AND NEAR LOS MOLINOS FROM BUTTE COUNTY LINE TO LOS MOLINOS CREEK BRIDGE |
| QA Service Level | 1 (Verified on 06/12/2025) |
Sample Information
| Sample Taken Date | 07/30/2026 | Sample Unique Key | 72 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/10/2026 | Sample type | Production Start-Up |
| A brief description of the sample | PG 64-16 Rubber Blend | The quantity of what the sample constitutes | 2 Quart Cans |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Tanner |
| Last name of sampler or witnessed by | CGI | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | JF Shea - Fawndale | |
| Transportation Laboratory (TL) Number | 681709 | Inspector Lot Number from the Transportation Laboratory (TL) Form | 681709 |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | American Pavement Systems |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | 25540 |
Test Details
DIME Sample ID: 2026-07-30-72
DIME Test ID: 2026-07-30-72-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2026-08-12
Test Results
Determination: Unworked Penetration
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 08/12/2026
Unworked Penetration, Test 1: 40 0.1 mm
Unworked Penetration, Test 2: 41 0.1 mm
Unworked Penetration, Test 3: 43 0.1 mm
Unworked Penetration: 41 0.1 mm
General comments (publicly viewable) (Max 1000 characters): CONE PENETRATION
Test was verified on 8/12/2026 ✔