Summary for Test 2026-08-07-25-1

Test performed: AASHTO T59-25

Project Information

Project IdentifiersProject ID: 1002538
DEA: 010P5404
EFIS: 0125000037
DIST-CO-RTE-PM01-HUM-101-R22.4/28
Award Date05/22/2026
Closeout DateNot set
Work DescriptionHM12200P540-Miranda Micro-Surfacing
Location DescriptionNear Miranda at French Road Undercrossing and from Salmon Creek Bridge to Myers Flat Separation
QA Service Level1 (Verified on 08/11/2026)

Sample Information

Sample Taken Date08/07/2026 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/10/2026
Sample typePreliminary A brief description of the sample4 quarts of MSE
The quantity of what the sample constitutes4, 1 quart plastic jugs From where was the sample collectedSource
First name of sampler or witnessed byUnknown No TL-101 Last name of sampler or witnessed byUnknown No TL-101
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTalley Oil Inc.- Madera, CA Transportation Laboratory (TL) NumberUnknown No TL-101
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown No TL-101 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeMSE
Lot NumberNot set Sub LotNot set
Dilution Percentage Rate100% pure

Test Details

DIME Sample ID: 2026-08-07-25
DIME Test ID: 2026-08-07-25-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-25: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2026-08-12

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 08/12/2026
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 146.5 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 115.1 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 145.7 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 114.1 g
Beaker 1 Residue: 62.8 %
Beaker 2 Residue: 63.2 %
Percentage of residue: 63 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 8/12/2026