Summary for Test 2026-08-11-36-3

Test performed: AASHTO T30-25

Project Information

Project IdentifiersProject ID: 1002407
DEA: 061H9304
EFIS: 0625000101
DIST-CO-RTE-PM06-KER-5-40.0/42.9, 52.8/62.6
Award DateNot set
Closeout DateNot set
Work DescriptionI-5 BUTTONWILLOW PAVEMENT REHAB (PM 40.0/42.9, 52.8/62.6): COLD PLANE, RHMA-G (BWC), HMA (TYPE A), PANEL REPLACEMENT, SHOULDER BACKING, RUMBLE STRIP, THERMO STRIPING, SIGNS, MODIFY TMS
Location DescriptionCONSTRUCTION ON STATE HIGHWAY IN KERN COUNTY IN AND NEAR BUTTONWILLOW FROM 1.2 MILES SOUTH OF ROUTE 5/43 SEPARATION TO 0.1 MILE SOUTH OF KERN RIVER UTILITY ROAD OVERCROSING AND FROM 0.7 MILE NORTH OF ROUTE 5/58 SEPARATION TO LERDO AVENUE OVERCROSING
QA Service Level1 (Verified on 07/13/2026)

Sample Information

Sample Taken Date08/11/2026 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/12/2026
Sample typeAcceptance A brief description of the sample3/8 HMA w RAP type A
The quantity of what the sample constitutesHMA+25%RAP L1SL3 From where was the sample collectedSource
First name of sampler or witnessed byAlex Last name of sampler or witnessed byEscober
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Solari Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item3957525

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number
Binder content (%)4.5 Virgin binder PGPG 64-16
Design binder PGPG 70-10 Binder SupplierSan Joaquin Refining Co.
RAP content (%)25 WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-08-11-36
DIME Test ID: 2026-08-11-36-3
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-08-12

Test Results


Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Has the fine aggregate sample been reduced?: No
Is an aggregate correction factor used?: Yes
Was the aggregate obtained using ASTM D8159?: No
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 08/12/2026
Total mass of material in the sample: 1988.8 grams
Cumulative mass retained on the 2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 in. sieve: 0.0 grams
Cumulative mass retained on the 3/4 in. sieve: 16.2 grams
Cumulative mass retained on the 1/2 in. sieve: 345.8 grams
Cumulative mass retained on the 3/8 in. sieve: 522.7 grams
Cumulative mass retained on the #4 sieve: 844.4 grams
Cumulative mass retained on the #8 sieve: 1105.0 grams
Cumulative mass retained on the #16 sieve: 1325.2 grams
Cumulative mass retained on the #30 sieve: 1521.3 grams
Cumulative mass retained on the #50 sieve: 1690.9 grams
Cumulative mass retained on the #100 sieve: 1804.1 grams
Cumulative mass retained on the #200 sieve: 1865.9 grams
Cumulative mass retained on the pan: 1874.1 grams
Aggregate correction factor for the 2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 3/4 in. sieve (% passing): 0.1 %
Aggregate correction factor for the 1/2 in. sieve (% passing): -0.9 %
Aggregate correction factor for the 3/8 in. sieve (% passing): -1.6 %
Aggregate correction factor for the #4 sieve (% passing): -2.3 %
Aggregate correction factor for the #8 sieve (% passing): -2.8 %
Aggregate correction factor for the #16 sieve (% passing): -1.5 %
Aggregate correction factor for the #30 sieve (% passing): 0.5 %
Aggregate correction factor for the #50 sieve (% passing): 0.1 %
Aggregate correction factor for the #100 sieve (% passing): 0.2 %
Aggregate correction factor for the #200 sieve (% passing): -0.1 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 82 %
Cumulative percent passing the 3/8 in. sieve: 72 %
Cumulative percent passing the #4 sieve: 55 %
Cumulative percent passing the #8 sieve: 42 %
Cumulative percent passing the #16 sieve: 32 %
Cumulative percent passing the #30 sieve: 24 %
Cumulative percent passing the #50 sieve: 15 %
Cumulative percent passing the #100 sieve: 9 %
Cumulative percent passing the #200 sieve: 6.1 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06_1H9304_37013_260811_L1SL3pdf282.86 KB08/12/20262026-08-11-36-3   Info

Test was verified on 8/12/2026