Summary for Test 2026-07-27-30-17

Test performed: ASTM F606-21
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 1001075
DEA: 040W0304
EFIS: 0420000164
DIST-CO-RTE-PM04-ALA-580-0.02/6.3
Award Date10/16/2025
Closeout DateNot set
Work DescriptionReplace existing tolling structure with open road tolling (ORT) system at the Richmond-San Rafael.
Location DescriptionNot set
QA Service Level1 (Verified on 03/13/2025)

Sample Information

Sample Taken Date07/27/2026 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing07/31/2026 Sample typeQuality Assurance
A brief description of the sample3/4 x 2-1/4 A325 The quantity of what the sample constitutes425
From where was the sample collectedFabricator First name of sampler or witnessed byJason
Last name of sampler or witnessed byGramlick Title of samplerASI
Telephone number of sampler916-639-5867 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameXKT Engineering
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)W000339200
Heat Number(s)1000134536 1000232161 190150106 Nut Mfg. Lot Number(s)W000319916
Washer Mfg. Lot Number(s)E9348 Bolt SpecificationASTM A325
Bolt Length(s)2-1/4 Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishHDG
Diameter/Size3/4 Bolt Mfg. Lot NumberW000339200
Rocap Test Requirement(s)W000339200 Lubricant Requirements(s)wax
Washer Inner Diameter(s)000 Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2026-07-27-30
DIME Test ID: 2026-07-27-30-17
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-08-18

Test Results


Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 08/12/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AE93480.755845000Nut Proof LoadWSP
21BE93480.755845000Nut Proof LoadWSP

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/18/2026 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.