Summary for Test 2026-07-29-58-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1002525 DEA: 113A9534 EFIS: 1125000170 |
|---|---|
| DIST-CO-RTE-PM | 11---unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/29/2026 | Sample Unique Key | 58 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/30/2026 | Sample type | Quality Assurance |
| A brief description of the sample | Plant Sample | The quantity of what the sample constitutes | 4 boxes |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Gerardo |
| Last name of sampler or witnessed by | Cordero | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Otay | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 226110 | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | 0 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-07-29-58
DIME Test ID: 2026-07-29-58-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-08-12
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 08/11/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4034.4 g
Mass of the specimen and specimen basket assembly prior to ignition: 6098.1 g
Mass of HMA Sample prior to ignition: 2063.7 g
Mass Loss: 171.8 g
Mass of aggregate remaining after ignition: 1891.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.75 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 358 C
Corrected Asphalt Binder Content: 7.57 %
General comments (publicly viewable) (Max 1000 characters): complies, oven 1
Test was verified on 8/12/2026 ✔