Summary for Test 2026-08-03-34-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1001565
DEA: 030J4404
EFIS: 0319000285
DIST-CO-RTE-PM03-BUT-162-15.6/18.5
Award Date12/04/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, HMA, MINOR CONCRETE, SIGNAL AND LIGHTING SYSTEM.
Location DescriptionBUTTE COUNTY IN OROVILLE FROM FEATHER RIVER BRIDGE TO FOOTHILL BOULEVARD
QA Service Level1 (Verified on 09/17/2025)

Sample Information

Sample Taken Date08/03/2026 Sample Unique Key34
Date that the sample was received by the laboratory/organization performing the testing08/04/2026 Sample typeQuality Assurance
A brief description of the sample3/4" HMA w/ 25% RAP The quantity of what the sample constitutes100 tons
From where was the sample collectedSupplier First name of sampler or witnessed bySergio
Last name of sampler or witnessed byTostado Title of samplerMaterials Tester
Telephone number of sampler8315884727 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Hallwood
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number30940132416P
Binder content (%)4.5 Virgin binder PGPG 58-22
Design binder PGPG 58-22 Binder SupplierPNW
RAP content (%)25 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2026-08-03-34
DIME Test ID: 2026-08-03-34-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-08-11

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 08/07/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2141.1 g
Mass Loss: 114.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.89 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.45 %
General comments (publicly viewable) (Max 1000 characters): R1 OBC 4.5%

Test was verified on 8/11/2026 ✔