Summary for Test 2026-07-28-74-1

Test performed: AASHTO T59-25

Project Information

Project IdentifiersProject ID: 1000697
DEA: 021J75U4
EFIS: 0224000092
DIST-CO-RTE-PM02-LAS-36-14.4/R16.8
Award Date01/23/2025
Closeout DateNot set
Work DescriptionPLACE HMA AND CLASS 2 AB, EXCAVATE ROADWAY, & INSTALL LIGHTING SYSTEM.
Location DescriptionLASSEN COUNTY ABOUT 9 MILES WEST OF SUSANVILLE FROM 1.3 MILES WEST TO 1.2 MILES EAST OF WILLARD CREEK ROAD
QA Service Level1 (Verified on 10/24/2024)

Sample Information

Sample Taken Date07/28/2026 Sample Unique Key74
Date that the sample was received by the laboratory/organization performing the testing08/07/2026 Sample typeQuality Assurance
A brief description of the sampleCQS-1 Emulsion The quantity of what the sample constitutes2 JUGS OF CQS-1
From where was the sample collectedJob Site First name of sampler or witnessed byD
Last name of sampler or witnessed byLOCKETT Title of samplerTECH
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAlbina - Klamath Falls, OR
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form846227
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeCQS-1
Lot Number1 Sub LotNot set
Dilution Percentage RateN/A

Test Details

DIME Sample ID: 2026-07-28-74
DIME Test ID: 2026-07-28-74-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-25: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2026-08-11

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 08/11/2026
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 146.2 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 114.5 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 144.6 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 115.1 g
Beaker 1 Residue: 63.4 %
Beaker 2 Residue: 59.0 %
Percentage of residue: 61 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 8/11/2026 ✔