Summary for Test 2026-07-28-80-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 993333 DEA: 04264724 EFIS: 0419000068 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101-R20.8/27.1 |
| Award Date | 04/26/2022 |
| Closeout Date | Not set |
| Work Description | CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
| Location Description | MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
| Sample Taken Date | 07/28/2026 | Sample Unique Key | 80 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/28/2026 | Sample type | Quality Assurance |
| A brief description of the sample | RHMA-O | The quantity of what the sample constitutes | HMA |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Ignacio |
| Last name of sampler or witnessed by | Arechiga | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Dutra | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | OGFC |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-07-28-80
DIME Test ID: 2026-07-28-80-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-08-11
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: casey farrington
Date of test: 07/28/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1634.7 g
Mass Loss: 121.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.36 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.91 %
General comments (publicly viewable) (Max 1000 characters): L2-SL11
Test was verified on 8/11/2026 ✔