Summary for Test 2026-07-16-84-1

Test performed: AASHTO T315-24

Project Information

Project IdentifiersProject ID: 1000481
DEA: 081C07U4
EFIS: 0824000168
DIST-CO-RTE-PM08-RIV-74-27.5/34.3
Award Date08/11/2025
Closeout DateNot set
Work DescriptionRUBBERIZED HMA, FIBER OPTIC CABLE SYSTEMS, AND COLD PLANE AC PAVEMENT.
Location DescriptionRIVERSIDE COUNTY AT AND NEAR ROMOLAND AND HOMELAND FROM BONNIE DRIVE TO WINCHESTER ROAD
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date07/16/2026 Sample Unique Key84
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2026
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byMaryanna Last name of sampler or witnessed byLandaverde
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMARTIN MARRIETA LAKE ELSINORE Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-07-16-84
DIME Test ID: 2026-07-16-84-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2026-08-11

Test Results


Phase: Original binder
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 08/10/2026
Phase Angle (δ) (for the 10 cycles): 85.7 degree
Dynamic Shear, G*/sin(δ): 1.42 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/11/2026