Summary for Test 2026-08-04-12-6
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 1002458 DEA: 09428604 EFIS: 0925000087 |
|---|---|
| DIST-CO-RTE-PM | 09-UNKNOWN--unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 07/23/2026) |
Sample Information
| Sample Taken Date | 08/04/2026 | Sample Unique Key | 12 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/04/2026 | Sample type | JMF Verification |
| A brief description of the sample | WRD, 3/8",3/4",1/2" aggregate stockpile | The quantity of what the sample constitutes | 4 bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Daniel |
| Last name of sampler or witnessed by | Enriquez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Griffith Edmonston | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-15-0068 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-08-04-12
DIME Test ID: 2026-08-04-12-6
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-08-11
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 08/11/2026
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1594.7 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 50.7 grams | 97 % | |||||
| 547.2 grams | 66 % | |||||
| 850.5 grams | 47 % | |||||
| 1024.5 grams | 36 % | |||||
| 1150.1 grams | 28 % | |||||
| 1264.0 grams | 21 % | |||||
| 1358.1 grams | 15 % | |||||
| 1433.1 grams | 10.1 % | |||||
General comments (publicly viewable) (Max 1000 characters): JMF-01 RAP
Test was verified on 8/11/2026 ✔