Summary for Test 2026-08-04-11-2
Test performed: AASHTO T209-25Project Information
| Project Identifiers | Project ID: 1002458 DEA: 09428604 EFIS: 0925000087 |
|---|---|
| DIST-CO-RTE-PM | 09-UNKNOWN--unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 07/23/2026) |
Sample Information
| Sample Taken Date | 08/04/2026 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/04/2026 |
| Sample type | JMF Verification | A brief description of the sample | 3/4" HMA |
| The quantity of what the sample constitutes | 24 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Enriquez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Griffith Company | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-08-04-11
DIME Test ID: 2026-08-04-11-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-08-11
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 08/06/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7306.4 grams
Mass of oven-dry sample in air for Sample 1: 2097.7 grams
Mass of container filled with the sample and water for Sample 1: 8590.0 grams
Temperature of Water: 77.3 °F
Specific Gravity for Sample 1: 2.577
Theoretical maximum density at 25°C (77°F): 160.4 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): JMF-01
Test was verified on 8/11/2026 ✔