Summary for Test 2026-07-13-22-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 1002024
DEA: 044AC704
EFIS: 0420000148
DIST-CO-RTE-PM04-MRN-101-8/15.3
Award DateNot set
Closeout DateNot set
Work DescriptionPAVEMENT - Repaving from Nellen to Miller Creek
Location DescriptionNot set
QA Service Level1 (Verified on 04/06/2026)

Sample Information

Sample Taken Date07/13/2026 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2026
Sample typeQuality Control A brief description of the sample3 4x8 concrete cylinders
The quantity of what the sample constitutes11.58 From where was the sample collectedJob Site
First name of sampler or witnessed byMohammed Salman Last name of sampler or witnessed byAlam
Title of samplerASR Telephone number of sampler(510) 435-4230
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameEcoTerra Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameMiller Creek (7B) Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number6SK4K1X425F
The truck number from where the sample was collectedNA The batch plant ticket number from where the sample was collectedNA
Concrete batch plantRichmond The fabricator/manufacturer designation for the sampleEcoterra ready mix
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-07-13-22
DIME Test ID: 2026-07-13-22-1
Testing Lab: CT HQ - Vallejo Field Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2026-08-10

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Nikhil Moon
Date of test: 08/10/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 87990 lb
Maximum load on cylinder 2: 87990 lb
Maximum load on cylinder 3: 87990 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 7000.0 psi
Compressive strength of cylinder 2: 7000.0 psi
Compressive strength of cylinder 3: 7000.0 psi
Compressive strength (to nearest 10 psi): 7000 psi
General comments (publicly viewable) (Max 1000 characters): Compression Testing Equipment Capacity is 7000 psi, strength of cylinder is > 7000 psi

Test was verified on 8/10/2026