Summary for Test 2026-07-27-58-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1002077 DEA: 033H5904 EFIS: 0318000017 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-80-R26.3/R55.2 |
| Award Date | 01/08/2026 |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/07/2026) |
Sample Information
| Sample Taken Date | 07/27/2026 | Sample Unique Key | 58 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/03/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #6 Coupler Gr. 80 |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Other |
| First name of sampler or witnessed by | NA | Last name of sampler or witnessed by | NA |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 80 | Rebar Manufacturer | Nucor |
| Coupler Manufacturer | NA | Intermediate Assembler or Fabricator | |
| Rebar Size | #6 | Coupler Model | NA |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | NA | Rebar Heat Number(s) | 1201071927 |
| Rebar Size 2 | Coupler Unique ID | SB-17-02 |
Test Details
DIME Sample ID: 2026-07-27-58
DIME Test ID: 2026-07-27-58-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2026-08-18
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 08/10/2026
UTM: NA
Halo ID: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1201071927 | 6 | 0.44 | 0.0011 | 51460 | 116955 | NA | Atlas |
| 2 | 2 | 1201071927 | 6 | 0.44 | 0 | 51130 | 116205 | NA | Atlas |
| 3 | 3 | 1201071927 | 6 | 0.44 | 0 | 51070 | 116068 | NA | Atlas |
| 4 | 4 | 1201071927 | 6 | 0.44 | 0 | 51510 | 117068 | NA | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2026 ✔