Summary for Test 2026-06-09-57-1

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 1001960
DEA: 081J65U4
EFIS: 0824000091
DIST-CO-RTE-PM08-RIV-10-0.0/R8.2
Award DateNot set
Closeout DateNot set
Work DescriptionHMA, RHMA, JPCP, JPCP(RSC), and individual slab replacement (RSC).
Location DescriptionNot set
QA Service Level1 (Verified on 03/23/2026)

Sample Information

Sample Taken Date06/09/2026 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/10/2026
Sample typeAcceptance A brief description of the sample3/4" HMA-A SP
The quantity of what the sample constitutes229.0 Tons @ 23:58 From where was the sample collectedManufacturer
First name of sampler or witnessed byPlant QC Last name of sampler or witnessed byPicked Up: Idris Najjar
Title of sampler Telephone number of sampler
Laboratory sample identification0322A-26 Linked DIME Sample ID2026-06-09-58
The fabricator/manufacturer/facility nameAll American Asphalt — Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number105793
Binder content (%)4.7 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-06-09-57
DIME Test ID: 2026-06-09-57-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-08-10

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Robert Jarquin
Date of test: 06/22/2026
Cumulative Mass RetainedCorrection FactorCumulative Percent Passing
2090.5 grams
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
82.9 grams0.5 %97 %
273.8 grams0.4 %87 %
488.0 grams-0.1 %77 %
987.2 grams-0.4 %52 %
1309.8 grams-0.9 %36 %
1544.9 grams-0.3 %26 %
1706.0 grams-0.1 %18 %
1825.4 grams-0.2 %12 %
1908.1 grams0.0 %9 %
1954.6 grams-0.1 %6.4 %
1965.0 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/10/2026