Summary for Test 2026-07-24-2-1

Test performed: ASTM A722-18

Project Information

Project IdentifiersProject ID: 1002369
DEA: 061K4404
EFIS: 0626000241
DIST-CO-RTE-PM06-FRE-168-L30.34/L30.84
Award Date06/01/2026
Closeout DateNot set
Work DescriptionRockslide Repair - Install four (4) bonded rock anchors at one (1) location. Bars to be 150 ksi, 1"-4 diameter/pitch, 12 ft long with 5 ft bond length.
Location DescriptionNot set
QA Service Level1 (Verified on 07/01/2026)

Sample Information

Sample Taken Date07/24/2026 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing07/24/2026 Sample typeQuality Assurance
A brief description of the sample1 inch ASTM A722 All-Thread Bar (150 ksi) Rock Anchor System with Hex Nut and Washer The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byPeter
Last name of sampler or witnessed byHarvey Title of sampler
Telephone number of sampler7073642452 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameJobsite
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB405
Structure unique identifier Structure name
Bid Item3956737

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size#8
Nut Specification for Threaded Bar150 ksi System ManufacturerWilliams Form Engineering
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsASTM A153 galvanized Bar Heat Number(s)58062582
Nut Heat Number(s)1000127644 Bar Lot Number
Nut Lot Number Coupler Heat Number(s)
Coupler Grade

Test Details

DIME Sample ID: 2026-07-24-2
DIME Test ID: 2026-07-24-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2026-08-10

Test Results


Number of Threaded Bar Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 08/07/2026
UTM: NA
Temperature: 0 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
111580625820.851633101254109.00NAWSP
221580625820.85156790134540033.29NAWSP

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/10/2026 ✔