Summary for Test 2018-04-27-3-5

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212862
DEA: 101G5504
EFIS: 1016000217
MINOR: 10A1892
DIST-CO-RTE-PM10-MPA-49-
Award DateNot set
Closeout Date12/28/2022
Work DescriptionConstruct two material storage bins
Location DescriptionNot set
QA Service Level1 (Verified on 12/11/2017)

Sample Information

Sample Taken Date04/27/2018 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing04/30/2018 Sample typeDepartment Acceptance
A brief description of the sample5/8 Bolt Assys The quantity of what the sample constitutes3 lots
From where was the sample collectedDistributor First name of sampler or witnessed byStacey
Last name of sampler or witnessed byDavis Title of samplerQAI
Telephone number of sampler5624806984 Laboratory sample identification
Linked DIME Sample ID2018-04-27-2 The fabricator/manufacturer/facility namePortland Bolt
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB362-028-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)109303-13, -14 and -15
Heat Number(s)NF16100430 NF16100430 CR10402430 Nut Mfg. Lot Number(s)27160-75068952
Washer Mfg. Lot Number(s)27160-75068952 Bolt SpecificationA325
Bolt Length(s)2, 3, 4.5 Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size5/8 Bolt Mfg. Lot Number374124A 374351A 762236
Rocap Test Requirement(s)Yes Lubricant Requirements(s)yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2018-04-27-3
DIME Test ID: 2018-04-27-3-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-05-10

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/02/2018
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A27160-750689525/8\"34537153.63Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 5/3/2018 ✔