Summary for Test 2018-04-27-2-15
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 212862 DEA: 101G5504 EFIS: 1016000217 MINOR: 10A1892 |
|---|---|
| DIST-CO-RTE-PM | 10-MPA-49- |
| Award Date | Not set |
| Closeout Date | 12/28/2022 |
| Work Description | Construct two material storage bins |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 12/11/2017) |
Sample Information
| Sample Taken Date | 04/27/2018 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/30/2018 | Sample type | Department Acceptance |
| A brief description of the sample | Anchor Bolt Assembly | The quantity of what the sample constitutes | 1 lot of 18 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Stacey |
| Last name of sampler or witnessed by | Davis | Title of sampler | QAI |
| Telephone number of sampler | 5624806984 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Portland Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-027-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | ATR- PL17106351 HHN - NF16100548 | Nut Mfg. Lot Number(s) | 380140A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 Gr 36 |
| Bolt Length(s) | Various | Nut Specification | A563 DH |
| Washer Specification | N/A | Finish | HDG |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | KG1790003170 |
| Rocap Test Requirement(s) | None | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2018-04-27-2
DIME Test ID: 2018-04-27-2-15
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-05-09
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/02/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | 380140A | 1/2\" | 21514 | 95.7 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 5/2/2018 ✔